为了使冷凝器在比较好的状态下运行,就必须对冷凝器进行专门的化学药物处理,清除水垢、锈蚀、粘泥、杀菌和防腐蚀处理,还原成清洁的金属表面。
In order to make the condenser run in a better state, the condenser must be treated with special chemical drugs to remove the scale, rust, mud, germicidal and corrosion prevention treatment, so as to restore the clean metal surface.
冷凝器清洗操作流程:
Condenser cleaning operation process:
1、关闭进出水阀门,打开排污阀,检查进出水阀关闭情况。
1, close the inlet and outlet valves, open the drain valve and check the closing of the inlet and outlet valves.
2、 打开冷凝器端盖,在铜管表面取一点水垢,用除垢剂剂做不同浓度配比的除垢试验。
2. Open the condenser end cover, take a little scale on the surface of the copper tube, and use scale remover to do the scale removal test with different concentration ratio.
3、 按低进高出方法,正确接好清洗泵。
3, according to the method of low in and out, correctly connect the cleaning pump.
4、利用外接水泵,往桶中注满水,启动清洗泵循环至水平稳。
4, use external pump, fill the water into the bucket, start cleaning pump to the level of stability.
5、 分次缓慢往桶中加YX-22除垢剂。循环后用自来水反复冲洗至 PH值 至7左右。
5, divide slowly into the bucket with YX-22 detergent. After recycling, rinse the tap water to pH value of 7.
6、用自来水冲洗清洗泵。
6. Rinse the pump with tap water.
7、 打开端盖使用亚欣全自动通炮机进行通炮。
7. Open the end cover and use the Yaxin automatic gun gun.